Molded Case Circuit Breaker(MCCB) with

Earth Leakage protection

 

LTZM1L series leakage circuit breaker (hereinafter referred to as circuit breaker) is mainly used in circuits with AC 50Hz, rated insulation voltage 800V, rated working voltage 400V, rated current 630A and below, to provide indirect contact protection for fatal electric shock, and also It can be used to prevent the fire hazard caused by the ground fault current caused by the insulation damage of the equipment. It can also be used to protect the line from overload, short circuit and undervoltage, and it can also be used for infrequent switching of the line.

 

 

1) There is no code for direct operation of the handle; D for electric operation; Z for rotary operation
2) 3: 3P; 3N: 3P+N; 4: 4P.
3) No code for leakage tripping without alarm: 1 for leakage alarm and tripping: for leakage alarm without tripping

 

 

Normal working conditions

Installation site: 2000m above sea level and below; ambient medium temperature is not higher than +40C and not lower than -5; and the 24-hour average value is not more than +35C (except for special orders).

Installation temperature, the relative humidity of the air should not exceed 50% when the maximum temperature is +40C: there can be a higher relative humidity at a lower temperature, for example, it can reach 90% at 20C. Special measures should be taken for occasional condensation due to temperature changes; the relative humidity of the humid tropical circuit breaker does not exceed 95% at +25C.

Pollution level: level 3.

Installation category: The installation category of the main circuit of the circuit breaker is 3, the auxiliary circuit and control circuit are not connected to the main circuit, and the installation category is 2.

The circuit breaker is suitable for the electromagnetic environment A.

Humid tropical circuit breakers can withstand the influence of damp heat, salt spray, and mold;
The circuit breaker should be installed in a place where there is no danger of explosion, no conductive dust, no corrosion of metal, and damage to insulation.

Where there is no rain or snow.

The circuit breaker should be installed according to the instruction manual of the product.

 

 

Main feature

The working power of the leakage protection module of the conventional circuit breaker is sampled as two phases, but this series of circuit breakers are three-phase. If any phase is missing, the leakage protection module of the circuit breaker can still work normally.

The rated residual operating current I△n and the maximum disconnection time can be adjusted on site according to the actual situation.

When the phase voltage drops to 50V, the leakage protection module can still work normally.

With leakage alarm output function.

The external volume is the same as that of the LTZM1L series circuit breakers, and the installation has good interchangeability.

 

 

 

 

Note:

1. Release mode and internal accessories code closing number: “2” indicates electromagnetic (instantaneous) release, “3” indicates thermal-electromagnetic (double) release; the last two digits indicate internal accessories code name.

2. Except that the auxiliary contacts of 220 and 320 specifications in TZM1L-400 and TZM1L-630 are two pairs of contacts (that is, two normally open and two normally closed), the number of auxiliary contacts of other specifications is a pair of contacts (that is, one normally open, normally closed).

 

 

Product Categories

According to the number of poles of the product, it is divided into three poles and four poles. There are four types of neutral poles (N poles) in four-pole circuit breakers:
Type A: The N pole is not equipped with an overcurrent release element, and the N pole is always connected and does not close and open with the other three poles;
Type B: No overcurrent release element is installed on the N pole, and the N pole is closed and opened together with the other three poles.
Type C: The N pole is equipped with an overcurrent release element, and the N pole is closed and opened together with the other three poles;
Type D: The N pole is equipped with an overcurrent release element, and the N pole is always connected and does not close and open with the other three poles.
According to the rated current (A): TZM1L-100 is (10), 16, 20, 25, 32, 40, 50, 63, 80, 100 ten grades;

TZM1L-225 has seven levels of 100, 125, 140, 160, 180, 200, and 225;
TZM1L-400 is 225, 250, 350, 315, 350, 400A six levels;
TZM1L-630 is 400, 500, 630A three-pole.
[with () is not recommended].

According to the connection mode, it is divided into three types: front-panel wiring, rear-panel wiring, and plug-in unwiring. According to the type of over-power release, it is divided into thermal-electromagnetic (complex) type and electromagnetic (instantaneous) type.

According to whether the circuit breaker has accessories, there are two types: with accessories and without accessories: accessories are divided into internal accessories and external accessories. Internal accessories include shunt release, Undervoltage release, leakage alarm unit module, auxiliary contact, and alarm contact. External accessories include a rotary handle operating mechanism and an electric operating mechanism.

 

Main technical parameters of circuit breaker

Model TZM1L-100 TZM1L-225
Frame current In m(A) 100 225
Rated current In(A) (10),16,20,25 32,40,50,63 80,100 100,125,140 160,180,200 225
Number of poles (P) 3 4 3 4
Rated insulation voltage Ui(V) AC800
Rated working voltage Ue(V) AC400 AC400
Rated impulse withstand voltage U imp(V) 8000 8000
Arcing distance(mm) ≥50 ≥50
Breaking capacity level L M H L M H
Ultimate short circuit breaking capacity Lcu(kA) AC400V 35 50 85 35 50 85
Operating short circuit breaking capacity Lcs(kA) AC400V 22 35 50 22 35 50
Rated residual operating current I△n(mA) Non-delayed (30)100/300/500
With delay 100/300/500
 Rated residual non-operating current
l△n(mA)
1
I△n
2
Rated residual short-circuit connection(short circuit) ability
l△n(kA)
1
I△n
4
Operating performance (times) Power on 1500 1000
Power off 8500 7000
W 92 122 107 142
L 150 150 165 165
H 92 92 90 90

 

Model TZM1L-400 TZM1L-630
Frame current In m(A) 400 630
Rated current In(A) 225, 250, 315 350, 400 400, 500, 630
Number of poles (P) 3 4 3 4
Rated insulation voltage Ui(V) AC800
Rated working voltage Ue(V) AC400 AC400
Rated impulse withstand voltage U imp(V) 8000 8000
Arcing distance(mm) ≥100 ≥100
Breaking capacity level L m h L m h
Ultimate short circuit breaking capacity Lcu(kA) AC400V 50 65 100 50 65 100
Operating short circuit breaking capacity Lcs(kA) AC400V 35 42 65 35 42 65
Rated residual operating current I△n(mA) Non-delayed (30)100/300/500
With delay 100/300/500 300/500/1000
 Rated residual non-operating current
l△n(mA)
1
I△n
2
Rated residual short-circuit connection(short circuit) ability
l△n(kA)
1
I△n
4
Operating performance (times) Power on 1000 1000
Power off 4000 4000
  W 150 198 210 280
L 257 257 280 280
h 106.5 106.5 115.2 115.5

1. Ultimate breaking capacity and arcing distance include horizontal installation and vertical installation;

2. When this series of three-pole circuit breakers are connected to a three-phase load, the load cannot be connected with a neutral line, including the load control circuit power source taken from the load end of the circuit breaker, and the neutral line cannot be provided, otherwise the circuit breaker will malfunction;

3. When this series of three-pole circuit breakers are under single-phase load, the phase line is connected to pole A, the neutral line is connected to pole C, and do not connect to pole B.

 